欢迎光临厦门雄霸电子商务有限公司官网!
10年工控行业经验PLC系统 DCS系统 伺服系统 机器人系统
全国咨询热线:15359298206
您的位置: 首页>>产品展示 >
产品展示 》 ICS Triplex 》 ICS TRIPLEX 9802/9300 可信通信接口模块 底板

ICS TRIPLEX 9802/9300 可信通信接口模块 底板

型号:9802/9300

联系人:周忆
公司名称:厦门雄霸电子商务有限公司
公司地址:福建省厦门市思明区吕岭路1733号2009单元(万科创想中心)
手机:15359298206
QQ:2641315943
邮箱:2641315943@qq.com

ICS TRIPLEX    9802/9300  可信通信接口模块 底板
ICS TRIPLEX    9802/9300  可信通信接口模块 底板

 
Brand Name ICS Triplex
Model  9802/9300
Product type N/M
Condition New
Gross Weight 1kg
Packing Size 11.8" x 7.9" x 9.9" (30 cm x 20 cm x 25 cm)
Country of Origin USA
Lead Time In Stock
Shipping Port Xiamen
Payment T/T
Sales Price Inquiry
Color Depends on material
Warranty 12 months
Lead time 3-7 work days
Courier partners DHL, UPS, TNT, FedEx and EMS


 
此版本中包含以下增强功能。
增加变量绑定内存
变量绑定(KVB)内存的大小已从64 K增加到128 K。这将允许您增加可以在应用程序中的控制器之间设置的变量绑定的数量。
适用于5个用户的新工作台许可证,无限制控制器新的许可证选项T9084U可用:这是适用于5用户的AADvanceWorkbench许可证,控制器数量没有限制。它只能作为USB许可证选项使用:它将与Windows XP Service Pack 3一起使用;Windows Vista;32位和64位版本的Windows 7和Server 2003。
以下问题和异常情况已在本版本中得到纠正。
数字输出模块关闭
9802/9300在某些操作和环境条件下,噪音可能
数字输出模块电压轨之一的存在。这些
对电压轨进行采样,以确保它们在特定范围内
容忍但噪声偶尔会导致监控电路
报告过电压,导致DO模块关闭。
改进了内部过滤器,减少了
噪音并防止模块关闭。
I/O初始化已暂停-TN30051-01(回答id 544046)
如果在控制器启动过程中发生I/O模块故障,则可能
停止I/O初始化。因此,控制器启动过程
未能完成,导致应用程序挂起。
已经对控制器启动进行了更改,以防止出现这种情况
防止发生。
48模块配置的系统通电
AADvance支持的大I/O模块数
控制器为48。某些配置,特别是当
大多数是数字输出模块,可能导致系统
电源循环后正确启动。控制器的更改
已经进行了启动以防止这种情况发生。
处理器失去同步
9802/9300 在双处理器配置中,在某些情况下是可能的
两个处理器失去同步的条件,但是
继续异步运行。尽管I/O仍然进入
在故障保护模式下,任何绑定数据都可能不正确。
已经对控制器进行了更改,以防止
发生。
杂散软错误检测(SED)故障-TN30056-01
(答案id:564815)
每个AADvance模块使用一个或多个FPGA来提供
处理器和I/O之间的通信接口
模块。AADvance中使用的FPGA的制造商
发布了一个产品通知,标识此设备可以
错误地生成SED错误。FPGA制造商
已对控制器进行了建议的更改,以防止
这种情况不会发生。
处理器在联机更新后失去同步
有可能对超过37的大型系统进行在线更新
安装的I/O模块可能会导致处理器丢失
同步。已对控制器进行了更改
防止这种情况发生。
SNCP内核变量绑定(KVB)通信丢失
在某些条件下,双SNCP的两个链路都有可能
绑定配置失败。已对控制器进行了更改
为了防止这种情况发生。
The following enhancements are included in this release.
Increase variable binding memory
The size of variable binding(KVB)memory has increased from 64 K to 128 K.This will allow you to increase the number of variable bindings that can be set between controllers in your application.
New workbench license for 5 users,unlimited controller New license option T9084U available:This is an AAdvanceWorkbench license for 5 users,with no limit on the number of controllers.It can only be used as a USB license option:it will be used with Windows XP Service Pack 3;Windows Vista;32-bit and 64-bit versions of Windows 7 and Server 2003.
The following issues and anomalies have been corrected in this version.
Digital output module shutdown
Under certain operating and environmental conditions,noise may
The presence of one of the voltage rails of the digital output module.these
Sample the voltage rails to ensure they are within a specific range
Tolerable but occasionally noise can cause monitoring circuitry
An overvoltage was reported,causing the DO module to shut down.
Improved internal filters,reduced
Noise and preventing the module from shutting down.
I/O initialization paused-TN30051-01(answer id 544046)
If an I/O module failure occurs during controller startup,it may be
Stop I/O initialization.Therefore,the controller starts the process
Failed to complete,causing the application to hang.
Changes have been made to the controller startup to prevent this situation
Prevent occurrence.
Powering up the 48 module configured system
Maximum number of I/O modules supported by AADvance
The controller is 48.Certain configurations,especially when
Most are digital output modules that may cause the system to
Start correctly after power cycle.Changes to the controller
A startup has been performed to prevent this from happening.
Processor out of sync
In a dual processor configuration,it is possible under certain circumstances
The two processors are out of sync,but
Continue to run asynchronously.Although I/O still enters
In failsafe mode,any binding data may be incorrect.
Changes have been made to the controller to prevent
happen.
Stray Soft Error Detection(SED)fault-TN30056-01
(Answer id:564815)
Each AAdvance module uses one or more FPGAs to provide
Communication interface between processor and I/O
modular.Manufacturer of FPGA used in AAdvance
A product notification has been issued identifying that this device can
Error generating SED error.FPGA Manufacturer
Proposed changes have been made to the controller to prevent
This will not happen.
The processor loses synchronization after an online update
It is possible to perform online updates on large systems exceeding 37
Installed I/O modules may cause processor loss
Synchronization.Changes have been made to the controller
Prevent this from happening.
SNCP kernel variable binding(KVB)communication loss
Under certain conditions,both links of a dual SNCP may be possible
Binding configuration failed.Changes have been made to the controller
To prevent this from happening.
ICS TRIPLEX	9802/9300  可信通信接口模块 底板
ICS TRIPLEX	9802/9300  可信通信接口模块 底板
其他相关型号:
ICS TRIPLEX T9100   ICS TRIPLEX T8310
ICS TRIPLEX TC-801-02-4M5   ICS TRIPLEX T8300
ICS TRIPLEX TC-305-01-5M0   ICS TRIPLEX T8231
ICS TRIPLEX TC-303-01-2M0   ICS TRIPLEX T8193
ICS TRIPLEX TC-301-02-2M0   ICS TRIPLEX T8191
ICS TRIPLEX TC-215-01-6M5   ICS TRIPLEX T8160
ICS TRIPLEX TC-215-01-4M5   ICS TRIPLEX T8151B
ICS TRIPLEX TC-201-01-6M5   ICS TRIPLEX T8110C
ICS TRIPLEX TC-201-01-4M5   ICS TRIPLEX T8110B
ICS TRIPLEX T9481   ICS TRIPLEX T8100
ICS TRIPLEX T9451   ICS TRIPLEX 9852*4 cable
ICS TRIPLEX T9432   ICS TRIPLEX 9852*4
ICS TRIPLEX T9402   ICS TRIPLEX 9852*3 cable
ICS TRIPLEX T9310-02 PN-175486   ICS TRIPLEX 9852*3
ICS TRIPLEX T9310-02   ICS TRIPLEX 9852*2/9832*1
ICS TRIPLEX T9110   ICS TRIPLEX 9852*1/9802*2 cable
ICS TRIPLEX T8480C   ICS TRIPLEX 9852*1/9802*2
ICS TRIPLEX T8461   ICS TRIPLEX 9852*1
ICS TRIPLEX T8451   ICS TRIPLEX 9852*1/9802*2
ICS TRIPLEX T8431C   ICS TRIPLEX 9832*3 cable
ICS TRIPLEX T8431   ICS TRIPLEX 9832*2 cable
ICS TRIPLEX T8403C   ICS TRIPLEX 9802*3 cable
ICS TRIPLEX T8403   ICS TRIPLEX 9802*1/9852*2 cable
ICS TRIPLEX T8314   ICS TRIPLEX 9802*3/9832*1 cable
ICS TRIPLEX T8312-4   ICS TRIPLEX 151661 4013-2255
ICS TRIPLEX T8311   ICS TRIPLEX 1433/09232486825
在线客服
联系方式

热线电话

15359298206

上班时间

周一到周五

公司电话

15359298206

二维码
线